10.9 System
Figure 209: Network Page: Interface Details
1. If necessary, click the Show link to show the interface details table.
2. For each device, select the MTU (Maximum Transmission Unit) frame size in the
Jumbo Frame MTU Size drop-down box.
1500
MTU
(Default) The standard (STD) MTU frame size of 1,500 bytes is used.
9000
MTU
The jumbo MTU frame size of 9,000 bytes is used. (For best performance, make
sure the entire network path to the ETERNUS CS800 is configured to use 9000
MTU.)
3. Click Update to save the changes you made to the Interface Details table. (Clicking
Update does not yet apply the new network settings to the ETERNUS CS800.)
4. Click Undo to revert to all current Interface Details changes to the last update.
Configuring Interface IP Addresses
Under IP Address Configuration > IP Address Table, configure one or more network
interfaces for each port or device (physical Ethernet port or bonded device) (see "Network
Page: IP Address Table" on page 327):
326 ETERNUS CS800