LED name LED status Description
POWER LED green
blinks green
AC power is supplied to the power supply unit.
AC power is supplied to the power supply unit, but
DC power is not supplied to the storage
subsystem.
FAULT LED amber AC power is not supplied to the power supply unit.
AC MISSING
LED
amber AC power is not supplied to this power supply
unit, but AC power is supplied to the other power
supply unit.
FANLED amber The power supply unit or the fan in the power
supply unit is in error status.
Table 11: Status and meanings of each LED (power supply unit)
For detailed information on ETERNUS JX40 S2 storage module see ETERNUS JX40
storage module manuals.
3.2.3 ETERNUS DX100 S3 Base Module - Front View
The Scale model of ETERNUS CS800 S6 uses ETERNUS DX100 S3 storage modules as
backup data storage. There are two variants of the ETERNUS DX100 S3 storage modules:
l a storage base module (controller enclosure) which is connected to the server
component, and up to ten optional
l storage expansion modules (drive enclosure) to provide additional capacity for backup
data.
The ETERNUS DX100 S3 base module contains 12 3.5-inch NL-SAS hard disk drives in the
front and one controller module and two power supplies in the rear.
DX100 S3 Base Module
Figure 34: Front view of the DX100 S3 controller enclosure