3.2 Storage Modules
Figure 35: Operation Panel (Controller Enclosure)
LED name LED status Description
POWER green DC power is supplied to the controller enclosure.
IDENTIFY blue blinking The installation location of the controller enclosure is
identified according to the instruction that is issued
from ETERNUS Web GUI or ETERNUS CLI.
FAULT amber The system is in error status.
blinks amber A part of the ETERNUS DX requires preventive
maintenance.
MAINTENANCE green Maintenance for the ETERNUS DX is in progress.
blinks green Maintenance or a status check via ETERNUS Web
GUI or ETERNUS CLI is necessary.
CACHE green There is data in the cache memory of the ETERNUS
DX.
READY green The ETERNUS DX is available for use..
Table 12: Status and Meanings of Each LED (Operation Panel - Base Module)
For detailed information on ETERNUS DX100 S3 storage module see ETERNUS DX100 S3
storage module manuals.
66 ETERNUS CS800