210
Chapter 8 Operation and Maintenance
Diskette drive A error This server has no floppy disk drive. If the messages appear, the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of the "Start Guide".
Diskette drive B error
Incorrect Drive A type - run SETUP
Incorrect Drive B type - run SETUP
System Cache Error - Cache disabled The cash error occurs in the system. Power off the server and
turn it back on. If the message still appears, check the error log
and replace the CPU if it is at fault. Or the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
Verify CPU Frequency selection in Setup The CPU is abnormal. Power off the server and turn it back on.
If the message still appears, check the error log and replace the
CPU if it is at fault. Or the baseboard must be replaced. Contact
an office listed in the "Contact Information" of the "Start
Guide".
System Management Configuration changed
The hardware configuration has changed or it is abnormal.
Change the [Reset Configuration Data] setting to [Yes] on the
"7.2.5 Advanced Menu" (p.183) of the BIOS Setup Utility.
Nevertheless, if the message still appears, replace the
corresponding part by checking the Server Management Tools.
Invalid System Configuration Data
The system configuration is abnormal. Change the [Reset
Configuration Data] setting to [Yes] on the "7.2.5 Advanced
Menu" (p.183) of the BIOS Setup Utility.
Operating system not found
The OS used for start up can not be found. Check that SAS/
RAID recognizes the device during POST. Or check that the
cables are properly connected.
Patch for installed CPU not loaded. Please run
the bios flash update diskette.
Check that the correct CPU is installed. If the correct CPU is
installed and the message still appears, BIOS requires an update.
Update the BIOS using updating tool supplied with new CPU. If
the message still appears, change the [Reset Configuration Data]
setting to [Yes] on the "7.2.5 Advanced Menu" (p.183) of the
BIOS Setup Utility. Nevertheless, if the message still appears,
the baseboard must be replaced. Contact an office listed in the
"Contact Information" of the "Start Guide".
PCI system error BUS/DEVICE/FUNCTION
nnnnh
The PCI bus is abnormal. Replace the components in the
following order: PCI card – baseboard – CPU
CPU had been changed - Run setup
This message may appear after replacing CPUs. Change the
[Reset Configuration Data] setting to [Yes] on the "7.2.5
Advanced Menu" (p.183) of the BIOS Setup Utility.
No Usable CPU Installed CPU error. Replace the CPU. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of "Start Guide". After the
replacement, enable the CPU in the BIOS Setup Utility.
No usable system memory The memory module is abnormal. System does not have any
usable memory modules. Check the error log and replace the
memory module. If the message still appears, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide". After the replacement, enable the
use of the memory in the BIOS Setup Utility.
Memory Redundancy Feature Could not
configure the Mirror DIMMs
The memory configuration is abnormal. Check that the memory
configuring the memory bank has the same capacity. If not, it
must be replaced.
table: List of POST error messages