211
PRIMERGY RX200 S4 User's Guide
Memory Redundancy Feature Could not
configure the spare DIMMs
The memory configuration is abnormal. Check that the memory
that configures the memory bank that makes up the hot spare has
the same capacity, or the spare memory has greater memory
capacity. If not, it must be replaced.
Application CPU timeout error The CPU is abnormal. Power off the server and turn it back on.
If the message still appears, check the error log and replace the
CPU if it is at fault. Or the baseboard must be replaced. Contact
an office listed in the "Contact Information" of the "Start
Guide".
Server Management Configuration NVRam
Bad - defaults loaded!
The contents of NVRam is abnormal. Correct the current
settings with the BIOS Setup Utility or turn the setting back to
the default. When the correct setting values are avoided by
Server Management Tools, restore it. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of the "Start Guide".
Baseboard Management Controller Error
The baseboard management controller is abnormal. Power off
the server, unplug the power cable, and then turn it back on. If
the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of the
"Start Guide".
PCI Express link width degraded
The PCI Express card is abnormal. Check that the PCI Express
card is properly installed. If it is properly installed and the
message still appears, replace the PCI Express card.
Nevertheless, if the message still appears, the baseboard or CPU
must be replaced. Contact an office listed in the "Contact
Information" of the "Start Guide".
USB Over current on HC
The current value of the USB is abnormal. Power off the server
and unplug the power cable. After that, turn it back on. If the
message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of the "Start
Guide".
Uncorrected CPU Machine Check
Architecture (MCA) error
The CPU is abnormal. Power off the server and turn it back on.
If the message still appears, check the error log and replace the
CPU if it is at fault. Or the baseboard must be replaced. Contact
an office listed in the "Contact Information" of the "Start
Guide".
Memory configuration has changed - Run
SETUP
The memory module is abnormal. The memory size has
changed since the previous booting. Check the error log and
replace the faulty memory module. If the message still appears,
the baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
Memory module failed! This module is no
longer available for the operating system.
The memory module is abnormal. Replace the faulty memory
module. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide". After the replacement, enable the use of the
memory in the BIOS Setup Utility
CPU disabled! CPU is no longer available for
the operating system.
The CPU is abnormal. The system does not have any usable
CPUs. Check the error log and replace the CPU. If the message
still appears, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide". After the
replacement, enable the use of the CPU in the BIOS Setup
Utility.
table: List of POST error messages
Message Description