Chapter 4 Operation of the Server 4-29
TABLE 4-5 lists setting items and the corresponding shell commands.
TABLE 4-5 External I/O Expansion Unit Administration
Item Description Shell Command Remarks
Display list Displays a list of External I/O Expansion
Units and cards in the host slot is identified by
the host_path to the card. The following is
displayed:
• Set External I/O Expansion Unit numbers
and downlink card paths
• External I/O Expansion Units, I/O boards,
link cards (Note 1), downlink cards, power
supply unit types, firmware versions, serial
numbers, part numbers, and states
ioxadm External I/O Expansion
Unit numbers are set in two
ways: specifying last four
digits of serial numbers
such as iox@nnnn, and
specifying instance
numbers such as ioxn.
Display
environment
information
Displays the status of the environment of the
specified External I/O Expansion Unit or
downlink card as sensor measurement values.
Also displays the environmentals of a FRU in
an I/O Expansion Unit or a card in a host slot.
The following is displayed:
•Current (A)
•Voltage (V)
•Fan speed (RPM)
•Temperature (C)
• LED state
•SWITCH
ioxadm Also, the preciseness is
displayed together with the
sensor measurement
values.