AquaTrans™ AT600 User’s Manual 175
Appendix A. Specifications
A.2 Electronics (cont.)
Outputs (Based on Configuration)
4-20 mA (24VDC powered, 600 maximum load, 1500 VDC isolation)
Frequency, Pulse, Alarm (Passive output, 100 VDC, 1 A/1 W maximum, 1500 VDC isolation)
HART (FSK modulation, Category Flow, Protocol Version 7.5, Device Revision 2, MFG ID 157,
Device Type Code 127, Number of device variables 34)
Modbus/RS485 (Half-duplex, 1500 VDC isolation)
Note: Analog outputs are Namur NE43 compliant.
Certification
CE, UL, CSA, (MCert approval pending)
A.3 Clamp-On Ultrasonic Flow Transducers
Materials
AT6 Transducer
Transducer Body: Aluminum (ASTM AL6061)
Fixture Body: Aluminum (ASTM AL6061)/Stainless Steel (ASTM A316)
C-RS Transducer
Transducer Body: Stainless Steel (ASTM A316)
Fixture Body: Stainless Steel
UTXDR Transducer
Transducer Body: Aluminum (ASTM AL6061)
Fixture Body: Aluminum (ASTM AL6061)/Stainless Steel (ASTM A304)
CF-LP Transducer
Transducer Body: Stainless Steel (ASTM A316)
Fixture Body: Aluminum (ASTM AL6061)
C-PT Transducer
Transducer Body: Stainless Steel (ASTM A316)
Fixture Body: Stainless Steel
Note: Contact BHGE for other transducer models.