Chapter 4. Initial Setup and Programming
84 AquaTrans™ AT600 User’s Manual
4.7.8 Programming the Fluid Type
If the fluid type is known, the meter performs flow rate calculations based on the programmed parameters
for that fluid. However, if the fluid type is not known, you must activate the
Tracking Windows function
described below. Relocating the transducers is not necessary.
Select
Fluid Type and press [√]. The following screen opens.
If the fluid type is water, select
Water and press [] to return to the
previous screen.
If the fluid is not water, select
Other and press []. A screen similar to the
following opens.
To disable the tracking window, select
No and press []. A screen similar
to the following opens, so that you can enter the speed of sound (
Fluid
SOS
.) in your fluid. If you don't know your Fluid SOS, you should enable
the
Tracking Window so that the meter can detect it automatically. If the
Tracking Window is enabled, select Yes and press [√]. A screen similar to
the following opens. Enter the
Maximum SOS and Minimum SOS.
Note:
Fluid SOS, Maximum SOS and Minimum SOS are all programmed in
the same manner.
Press
[] again, and a screen similar to the following opens.
Use the [] or [] key to select a specific digit, then use the [] or [] key
to change that digit as required. After all digits are correct, press
[] to
save. Then, press [
] to return to the previous screen.
Sensor Setup
Traverses
Fluid Type
Fluid Temperature
Path
Fluid SOS
Fluid SOS
1496.000 m/s
Fluid SOS
UNIT: m/s
1496.000
]MOVE
]UNDO [ ]SAVE
]
]
]MODF
[