Concord 4 Series Systems
27
Installer Code (0001)
Security-Global (Default = 4321)
The 4-digit installer code is used for entering program mode and changing
system settings. If a dealer code is programmed, only those settings not
associated with phone numbers and the Downloader Code can be changed.
Note
The Installer Code cannot be deleted or cleared from panel memory. To change
the Installer Code to its default setting, enter 4321.
To program a Installer Code:
1. With the display showing INSTALLER CODE
nnnn
(current code), enter the desired 4-digit
code. The display flashes the entered code.
2. Press # and the display shows the new code.
Dealer Code (0002)
Security-Global (Default = none)
The 4-digit dealer code is used to prevent unauthorized per-
sons from changing the programmed central station phone
numbers and Downloader Code. When this feature is enabled,
central station phone numbers and Downloader Code cannot
be changed (unless you enter the program mode by using the
dealer code). All other system settings are still accessible by
entering the program mode with the installer code.
Note
The Dealer Code cannot be deleted by clearing panel memory.
To program a Dealer Code:
1. With the display showing DEALER CODE ****, enter the
desired 4-digit code. The display flashes the entered
code.
2. Press # and the display shows the new code.
To delete a Dealer Code:
1. With the display showing DEALER CODE nnnn (current
code), press D. The display shows
DEALER CODE ****.
Access Code Lock (0003)
Security-Global (Default = on)
This setting determines whether or not the panel will include Access
Codes when sending user information to the automation module. When
this option is on, it means the Access Codes are not sent.
To turn Access Code Lock off or on:
1. With the display showing ACCESS CODE LOCK
ON/OFF
, press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
Partition Security (0004)
Security-Global (Default = on)
Controls whether an access code is required for partition jumping. When turned
on, users must jump partitions with an access code by pressing 8 + CODE + 6 +
PTN. When turned off, users can jump partitions without an access code by
pressing 7 + 4 + PTN n (n = 1-6).
Note
Regardless of the setting, an access code can always be used to jump partitions.
To turn Partition Security off or on:
1. With the display showing PTN SECURITY
(current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new
setting.
WWW.DIYALARMFORUM.COM

Table of Contents

Other manuals for GE Concord 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 Series and is the answer not in the manual?

GE Concord 4 Series Specifications

General IconGeneral
User Codes230
Backup Battery12V 4Ah rechargeable battery
Wireless Frequency319.5 MHz
CommunicationPOTS, optional cellular and IP modules
Wireless CapabilityYes
Keypad OptionsMultiple keypad options including touchscreen
Wired Zones8 on board
Power Supply16.5 VAC Transformer
CompatibilityCompatible with GE Security wireless sensors
ZonesUp to 96
Event Buffer512