EasyManuals Logo

GE Concord 4 Series Installation Instructions

GE Concord 4 Series
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Concord 4 Series Systems
3
The following table describes non-programmable (hard coded) system operation as required to
meet ANSI-SIA CP-01 and is provided only for your reference.
Note
Silent arming feature may be used to supress arming level and exit beeps for the current arming period
only. Refer to user guide for more information on silent arming.
Commercial Burglary Alarm System Unit (Grade B UL 1610)
Basic system using Control Panel 600-1040, SuperBus 2000 RF Transceiver Module (600-1025-
01-95R), plus:
Hardwire Magnetic Contact (13-068 or 13-071) or Wireless Learn Mode Door/Window
Sensor (60-499)
SAW PIR Sensor (60-639-95R), Crystal PIR Sensor (60-703-95R), or DS924i PIR Sensor
(60-511-01-95)
UL Grade A Bell/Housing such as Ademco #AB12M or equivalent
Immediate Beeps set to on
UL 98 Options set to on
Receiver Failure set to on (if wireless devices are used)
RF TX Timeout set to 4 hours
24-Hour Tamper set to on
System Tamper set to on
Auto Phone Test set to on
Phone Test Freq. set to 1
Next Phone Test set to 1
Siren Verify set to on
AC Failure set to on
Exit Delay set to 120 seconds or less
Quick Exit set to off
Two Trip Error set to off
Alarm Verify set to off
Disable Trouble Beeps set to off
Phone Number must be programmed
High Level Rpts set to on
Low Level Rpts set to on
Comm. Failure set to on
Extended Delay set to off
Sleep Time set to off
Siren Timeout set to 4 minutes or more
UL 1610 24-Hour Backup
Same as UL 1023 & 985
UL 1635 Digital Alarm Communicator System
Note
For UL 1635 installations,
Entry Delay plus Dialer
Abort Delay must not
exceed 60 seconds.
Same as UL 1023, 985 & 1610 plus:
AC Failure set to on
Phone Number must be programmed
Low CPU Battery set to on
Next Phone Test set to 1
Function Operation
SIA False Alarm Enabled
Auto Stay Arming Enabled
Disarm During Entry Delay Enter Code Only (or 1 + CODE)
Cancel Alarm Enter Code Only (or 1 + CODE)
Abort Annunciation Enabled
Entry/Exit Progress Annunciation Enabled
WWW.DIYALARMFORUM.COM

Table of Contents

Other manuals for GE Concord 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 Series and is the answer not in the manual?

GE Concord 4 Series Specifications

General IconGeneral
User Codes230
Backup Battery12V 4Ah rechargeable battery
Wireless Frequency319.5 MHz
CommunicationPOTS, optional cellular and IP modules
Wireless CapabilityYes
Keypad OptionsMultiple keypad options including touchscreen
Wired Zones8 on board
Power Supply16.5 VAC Transformer
CompatibilityCompatible with GE Security wireless sensors
ZonesUp to 96
Event Buffer512

Related product manuals