Concord 4 Series Systems
49
Latchkey Format (06105 - 06605)
Reporting-Partition 1-6 (Default = off)
(Default = off) This setting determines whether the selected partition is set up for
basic (off) or advanced (on) latchkey opening report operation.
Basic:
If the partition is armed by entering 2 (or
3) + CODE, disarming using a desig-
nated latchkey user code or keychain touchpad within an assigned time schedule
sends a page.
Arming the partition by entering 2 (or
3) + CODE + 6 (Latchkey) sends a page.
If the partition is armed by entering 2 (or
3) + CODE + 6 (Latchkey), disarming
using a designated latchkey user code or keychain touchpad inside or outside of
an assigned time schedule sends a page.
Advanced:
Arming the partition by entering 2 (or
3) + CODE + 6 (Latchkey) within an
assigned time schedule sends a page.
If the partition is armed by entering 2 (or
3) + CODE + 6 (Latchkey), disarming
using a latchkey designated user code or keychain touchpad within an assigned
time schedule sends a page.
Refer to the Users Guide for complete Latchkey setup and operation.
To turn Latchkey Format off or on:
1. With the desired partition selected,
press A or B until the display shows
LATCHKEY FORMAT OFF/ON (current
setting).
2. Press 1 (off—basic) or 2 (on—
advanced). The display flashes the
entered setting. Press # and the dis-
play shows the new setting.
Freeze Alarm (06106 - 06606)
Reporting-Partition 1-6 (Default = off)
This setting determines whether the panel reports a freeze alarm to the
central station or pager, when the selected partition’s energy saver
module detects a temperature that matches a predetermined setting (see
BUS DEVICES—UNIT ID—ENERGY OPTIONS—FREEZE TEMP, or
FREEZE TEMP below
).
To turn Freeze Alarm reporting off or on:
1. With the desired partition selected, press A or B
until the display shows
FREEZE ALARM OFF/ON
(current setting).
2. Press 1 (off) or 2 (on). The display flashes the
entered setting. Press # and the display shows
the new setting.
Freeze Temp (06107 - 06607)
Reporting-Partition 1-6 (Default = 42
°
F)
This setting determines the temperature point the Energy Saver Module
detects a potential freeze (heating failure) condition. The adjustable
range is from 40
°
- 90
°
F.
Note
This is the same menu found under ACCESSORY MODULES/BUS
DEVICES/UNIT ID/ENERGY OPTIONS.
To set the Freeze Temp:
1. With the desired partition selected, press A or B
until the display shows
FREEZE TEMP (current
setting).
2. Enter the desired temperature (40-90). The dis-
play flashes the entered setting. Press # and the
display shows the new setting.
Alarm Verify (06108 - 06608)
Reporting-Partition 1-6 (Default = off)
This setting determines whether the panel reports to the central moni-
toring station after a single sensor or zone trip (off) or waits for a sec-
ond trip before reporting (on).
This setting affects sensors/zones in groups 10 through 20. If Alarm
Verify is set to on, group 18 responds the same as group 17 (see
“Appendix B, Table B1 “Sensor Group Characteristics”).
Note
For UL Listed installations, Alarm Verify must be set to off.
To turn Alarm Verify off or on:
1. With the display showing ALARM VERIFY OFF/ON
(current setting), press 1 (off) or 2 (on). The dis-
play flashes the entered setting.
2. Press # and the display shows the new setting.
WWW.DIYALARMFORUM.COM

Table of Contents

Other manuals for GE Concord 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 Series and is the answer not in the manual?

GE Concord 4 Series Specifications

General IconGeneral
User Codes230
Backup Battery12V 4Ah rechargeable battery
Wireless Frequency319.5 MHz
CommunicationPOTS, optional cellular and IP modules
Wireless CapabilityYes
Keypad OptionsMultiple keypad options including touchscreen
Wired Zones8 on board
Power Supply16.5 VAC Transformer
CompatibilityCompatible with GE Security wireless sensors
ZonesUp to 96
Event Buffer512