Concord 4 Series Systems
73
Table 10 describes pager sensor/zone number and user number report codes.
Testing Outputs and Sirens
All outputs (onboard and SnapCard) should be tested to verify configuration programming.
Be sure to contact the central monitoring station before activating outputs that trigger
from an alarm condition.
To test outputs:
1. Contact the central monitoring station to inform them you are testing the system.
2. Verify that all wiring at the panel and output devices is correct.
3. Activate the appropriate device to trigger each output as programmed.
4. Verify that each output responds according to the programmed configuration number. For
outputs that trigger sirens, verify that the correct alarm sounds are produced from these
sirens. Table 11 describes the system alarm sounds you should hear for each alarm event.
5. Contact the central monitoring station when you are finished testing.
Table 9: Pager System Event Codes
Code System Event
009 Zone Restoral
111 System Disarmed
115 Sensor Test Exit
118 Trouble condition cleared
119 Alarm Canceled
222 System Armed to STAY
333 System Armed to AWAY
555 Phone/Sensor Test
888 System Trouble Condition
999 System in Alarm
Table 10: Pager Sensor/Zone Code and Numbers
Code Sensor/Zone or User Number
000 System event not caused by a zone or user
001–096 Sensor/Zone Numbers 1–96
600–829 Regular User Codes 0–229 used
830-837 Partition Master Code used
838-845 Partition Duress Code used
846 System Master Code used
847 Installer Code used
848 Dealer Code used
850 Quick Arm used
851 Keyswitch Sensor used
852 System Armed Itself (during service or power-up)
Table 11: System Alarm Sounds
Alarm Type Alarm Sound
Fire Repeating series of three beeps
Police/Intrusion Continuous tone
Auxiliary Rapid beeps
Caution
!
WWW.DIYALARMFORUM.COM

Table of Contents

Other manuals for GE Concord 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 Series and is the answer not in the manual?

GE Concord 4 Series Specifications

General IconGeneral
User Codes230
Backup Battery12V 4Ah rechargeable battery
Wireless Frequency319.5 MHz
CommunicationPOTS, optional cellular and IP modules
Wireless CapabilityYes
Keypad OptionsMultiple keypad options including touchscreen
Wired Zones8 on board
Power Supply16.5 VAC Transformer
CompatibilityCompatible with GE Security wireless sensors
ZonesUp to 96
Event Buffer512