EasyManuals Logo

GE Concord 4 Series Installation Instructions

GE Concord 4 Series
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Concord 4 Series Systems 44
Reporting Menu
The REPORTING menu lets you set up which system events are reported to the central monitoring
station. The following describes how to program the settings that appear under
GLOBAL.
Star Is No Delay (0514 - 0564)
Touchpad Options-Partitions 1-6 (Default = off)
This setting determines whether the keychain touchpad star button
controls an output (off) or the No Delay feature (on).
To change the keychain Star Is No Delay setting:
1. With the display showing STAR IS NO DELAY OFF/ON
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
24-Hour Tamper (06000)
Reporting-Global (Default = off)
Note
Tamper conditions for fire sensors (group 26) always cause trouble
beeps to sound and report the tamper condition to the central station,
regardless of this feature setting.
When turned on, the panel sounds sirens and reports a tamper alarm
(even when the system is disarmed), when non-fire wireless sensor
tamper switches are activated.
When turned off, the panel sounds sirens and reports a tamper alarm
only when non-fire wireless sensor tamper switches are activated
and those sensors are active for the current arming level. For non-
fire sensors not active in the current arming level that have their
tamper switch activated, trouble beeps sound and the panel sends a
sensor tamper report to the central station if the System Tamper fea-
ture is on for that partition.
Note
For commercial UL Listed installations (UL 1610) the 24-Hour Tamper
must be set to on.
To turn 24-Hour Tamper off or on:
1. With the display showing 24 HOUR TAMPER OFF/ON
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
Antenna Tamper (06001)
Reporting-Global (Default = off)
Determines whether the panel monitors for antenna tamper of
onboard and all connected bus transceivers and receivers.
When turned on, the panel sounds trouble beeps in all partitions and
reports an antenna tamper condition. Touchpads in all partitions
show a receiver tamper trouble condition.
When turned off, the panel ignores antenna tampers.
Note
If the system includes SuperBus 2000 RF Receivers, this setting must
be off.
To turn Antenna Tamper off or on:
1. With the display showing ANTENNA TAMPER OFF/ON
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
Buffer Control (06002)
Reporting-Global (Default = off)
When this setting is on, only arming level changes and time
changes (system time and daylight savings time) are logged in the
buffer (memory) of the panel. When this setting is off, all system
events are logged in the buffer.
To turn Buffer Control off or on:
1. With the display showing BUFFER CONTROL OFF/ON
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
WWW.DIYALARMFORUM.COM

Table of Contents

Other manuals for GE Concord 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 Series and is the answer not in the manual?

GE Concord 4 Series Specifications

General IconGeneral
User Codes230
Backup Battery12V 4Ah rechargeable battery
Wireless Frequency319.5 MHz
CommunicationPOTS, optional cellular and IP modules
Wireless CapabilityYes
Keypad OptionsMultiple keypad options including touchscreen
Wired Zones8 on board
Power Supply16.5 VAC Transformer
CompatibilityCompatible with GE Security wireless sensors
ZonesUp to 96
Event Buffer512