EasyManuals Logo

GE Concord 4 Series Installation Instructions

GE Concord 4 Series
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
Concord 4 Series Systems 48
Closing Reports (06101 - 06601)
Reporting-Partition 1-6 (Default = off)
When this setting is on, the panel sends a closing report to the central
station after arming the system.
Note
To use this feature, the Open/Close Reports settings under the
PHONES
menu must be turned on for the specific CS Phone or Pager number.
To turn Closing Reports off or on:
1. With the display showing CLOSING REPORTS
OFF/ON
(current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new setting.
No Activity (06102 - 06602)
Reporting-Partition 1-6 (Default = off)
When this setting is on, the panel sends a no activity report to the cen-
tral station when the activity timeout expires (see
TIMERS—ACTIVITY
TIMEOUT
).
To turn No Activity reports off or on:
1. With the display showing NO ACTIVITY OFF/ON
(current setting), press 1 (off) or 2 (on). The dis-
play flashes the entered setting.
2. Press # and the display shows the new setting.
Duress Option (06103 - 06603)
Reporting-Partition 1-6 (Default = off)
(Default = off) When this setting is on, the system can be controlled
using a programmed duress code (see
SECURITY—PARTITION N—
DURESS CODE
) and will send a duress alarm to the monitoring station.
Note
For UL Listed installations, Duress Option must be set to off.
Do not use a duress code unless it is absolutely necessary. Using duress
codes often results in false alarms due to code entry errors. If a duress
code is absolutely necessary, use it with the audio verification module
to reduce false alarms and accidental dispatches.
To turn Duress Option off or on:
1. With the display showing DURESS OFF/ON (cur-
rent setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
Force Armed (06104 - 06604)
Reporting-Partition 1-6 (Default = off)
When this setting is on, the panel reports to the central monitoring station when a
user “force arms” the system.
Note
Forced arming occurs if the user presses BYPASS when arming the system with open
sensors/zones protesting.
Auto-forced arming occurs when the user does not press BYPASS when arming the sys-
tem with open sensors/zones protesting, then leaves through an entry/exit door and the
arming protest period expires. This causes the system to automatically bypass the open
(protesting) sensors.
Auto-forced arming always reports to the central monitoring station.
Auto-forced arming has not been investigated by UL.
To turn Force Armed off or on:
1. With the display showing FORCE
ARMED OFF/ON
(current setting),
press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the
new setting.
WWW.DIYALARMFORUM.COM

Table of Contents

Other manuals for GE Concord 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 Series and is the answer not in the manual?

GE Concord 4 Series Specifications

General IconGeneral
User Codes230
Backup Battery12V 4Ah rechargeable battery
Wireless Frequency319.5 MHz
CommunicationPOTS, optional cellular and IP modules
Wireless CapabilityYes
Keypad OptionsMultiple keypad options including touchscreen
Wired Zones8 on board
Power Supply16.5 VAC Transformer
CompatibilityCompatible with GE Security wireless sensors
ZonesUp to 96
Event Buffer512