Concord 4 Series Systems 32
High Level Rpts (cs phone 1: 01001, cs phone 2: 01011,
cs phone 3: 01021)
Phones-CS 1-3 (Defaults:1 = on, 2&3 = off)
When this setting is on, the following conditions report to the central sta-
tion:
Fire, Police, Auxiliary, and Duress alarms
No Activity
Receiver Failure (or jam)
Tamper conditions, including Zone Tampers and System Tamper (40
incorrect key presses or touchpad supervisory)
Entering or exiting Sensor Test mode
Phone Test
Note
For UL 1610 & 1635 installations, this feature must be set to on.
To turn High-Level Reports off or on:
1. With the display showing HIGH LEVEL RPTS
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new set-
ting.
Low Level Rpts (cs phone 1: 01002, cs phone 2: 01012,
cs phone 3: 01022)
Phones-CS 1-3 (Defaults:1 = on, 2&3 = off)
When this setting is on, the following non-alarm conditions report to the
central station:
Force Armed
Hardwire Zone Trouble (open or short)
Supervisory (wireless devices)
Low Battery (wireless devices)
Phone Test
Other non-alarm related conditions
Note
For UL 1610 & 1635 installations, this feature must be set to on.
To turn Low-Level Reports off or on:
1. With the display showing LOW LEVEL RPTS
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new set-
ting.
Exception Rpts (cs phone 1: 01003, cs phone 2: 01013,
cs phone 3: 01023)
Phones-CS 1-3 (Default = off)
When this setting is on, the panel reports to the central station if the sys-
tem is not armed or disarmed at the specified schedule times.
To turn Exception Reports off or on:
1. With the display showing EXCEPTION RPTS
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new setting.
Open/Close Rpts (cs phone 1: 01004, cs phone 2: 01014,
cs phone 3: 01024)
Phones-CS 1-3 (Default = off)
This setting determines whether opening and closing reports are sent to
the central station. When turned on, the panel sends a closing report when
the system is armed and an opening report when the system is disarmed.
Note
To use this feature, the Opening Reports and Closing Reports settings under
the
REPORTING menu must be turned on for that partition.
To turn Opening/Closing Reports off or on:
1. With the display showing OPEN/CLOSE RPTS
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new set-
ting.
WWW.DIYALARMFORUM.COM

Table of Contents

Other manuals for GE Concord 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 Series and is the answer not in the manual?

GE Concord 4 Series Specifications

General IconGeneral
User Codes230
Backup Battery12V 4Ah rechargeable battery
Wireless Frequency319.5 MHz
CommunicationPOTS, optional cellular and IP modules
Wireless CapabilityYes
Keypad OptionsMultiple keypad options including touchscreen
Wired Zones8 on board
Power Supply16.5 VAC Transformer
CompatibilityCompatible with GE Security wireless sensors
ZonesUp to 96
Event Buffer512