Concord 4 Series Systems 40
Phone Test Freq. (0303)
Timers-Global (Default = 7 days)
This setting determines how often the panel conducts the automatic phone
test (see “Auto Phone Test” under
PHONE OPTIONS—GLOBAL). The sys-
tem can be set to perform an automatic phone test anywhere from every
day to every 255 days.
Note
For UL 1610 & 1635 listed installations, this feature must be set to 1.
To set the Phone Test Freq:
1. With the display showing PHONE TEST FREQ
nnn DAYS
(current setting), enter the number
of days (1–255). The display flashes the
entered setting.
2. Press # and the display shows the new setting.
Next Phone Test (0304)
Timers-Global (Default = 7 days)
This setting is used by the Auto Phone Test feature (see
PHONE
OPTIONS—GLOBAL
) to determine when the next automatic phone test
should occur. This setting should be the same as, or less than, the Phone
Test Freq. setting.
Note
For UL 1610 & 1635 listed installations, this feature must be set to 1.
To set the Next Phone Test:
1. With the display showing NEXT PHONE TEST
nnn DAYS
(current setting), enter the number
of days (1–255). The display flashes the
entered setting.
2. Press # and the display shows the new setting.
Output Trip Time (0305)
Timers-Global (Default = 4 sec.)
This setting determines how long outputs are activated
when tripped (if they are configured for a momentary
response).
To set the Output Trip Time:
1. With the display showing OUTPUT TRIP TIME nn SECS (current
setting), enter the number of seconds (1–12). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
Activity Timeout (0306)
Timers-Global (Default = 24 hours)
This setting determines when the system sends a “no activity” report.
The panel can be set to wait from 1–42 hours. If no user interaction or
device activation occurs in that time, the panel sends a report to the cen-
tral station.
To set the Activity Timeout:
1. With the display showing ACTIVITY TIMEOUT
nn HOURS
(current setting), enter the number
of hours (1–42). The display flashes the
entered setting.
2. Press # and the display shows the new setting.
Daylight Saving (0307)
Timers-Global (Default = on)
When this setting is on, the panel clock automatically adjusts for daylight
saving time changes.
To turn Daylight Saving off or on:
1. With the display showing DAYLIGHT SAVING
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new setting.
WWW.DIYALARMFORUM.COM

Table of Contents

Other manuals for GE Concord 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 Series and is the answer not in the manual?

GE Concord 4 Series Specifications

General IconGeneral
User Codes230
Backup Battery12V 4Ah rechargeable battery
Wireless Frequency319.5 MHz
CommunicationPOTS, optional cellular and IP modules
Wireless CapabilityYes
Keypad OptionsMultiple keypad options including touchscreen
Wired Zones8 on board
Power Supply16.5 VAC Transformer
CompatibilityCompatible with GE Security wireless sensors
ZonesUp to 96
Event Buffer512