Concord 4 Series Systems 88
Low CPU Battery On 06005
Low Level Reports (phones) CS Phone 1 On, CS Phone
2-3 Off
01002, 01012,
01022
1_____________2_____________3___________
Low Level Reports (pagers) Off
01032, 01042,
01052, 01062,
01072
1_____________2_____________3___________
4_____________5____________
Manual Mic Gain 09009
Multi-PTN Arm Off 0005
Next Phone Test 7 days 0304
No Activity Off 06102 - 06602
Open/Close Reports (phones) Off
01004, 01014,
01024
1_____________2_____________3___________
Open/Close Reports (pagers) Off
01034, 01044,
01054, 01064,
01074
1_____________2_____________3___________
4_____________5_____________
Opening Reports Off 06100-06600
Onboard Output 1 01614- any audible alarm 11101
Onboard Output 2 01710 - status & alarm tones 11111
Output Trip Time 4 sec 0305
Pager Delay 15 sec 02008
Pager Partition Assignment 1
01037, 01047,
01057, 01067,
01077
1_____________2_____________3___________
4_____________5_____________
Pager Phone 1-5 None
01030, 01040,
01050, 01060,
01070
1_____________2_____________3___________
4_____________5_____________
Partition Security On 0004
Phone Access Key # 0216-0266
Phone Panic Off 0215-0265
Phone Test On 02000
Phone Test Freq. 7 days 0303
Police Panic On 0512-0562
Program Report Off 06015
Quick Arm Off 0011-0061
Quick Exit On 0012-0062
Receiver Failure Off 06012
Remote Access On 0211-0221
RF Low Battery Rpt Weekly 06013
RF Supervisory Rpt Weekly 06014
RF TX Timeout 12 hrs 0302
Ring/Hang/Ring On 0212-0262
Reporting Format (SIA/CID) CID
01006, 01016,
01026
1_____________2_____________3___________
Sensor Text None 081
Silent Talkback Off 09003
Siren Timeout 4 min 0313-0363
Siren Verify Off 0710
Sleep Time Off 0314-0364
Smoke Verify Off 1100
Table A4: System Settings Index and Record (Continued)
Setting (reference) default Shortcut No. Setting
WWW.DIYALARMFORUM.COM

Table of Contents

Other manuals for GE Concord 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 Series and is the answer not in the manual?

GE Concord 4 Series Specifications

General IconGeneral
User Codes230
Backup Battery12V 4Ah rechargeable battery
Wireless Frequency319.5 MHz
CommunicationPOTS, optional cellular and IP modules
Wireless CapabilityYes
Keypad OptionsMultiple keypad options including touchscreen
Wired Zones8 on board
Power Supply16.5 VAC Transformer
CompatibilityCompatible with GE Security wireless sensors
ZonesUp to 96
Event Buffer512