MDS 05-6632A01, Rev. F MDS Orbit MCR/ECR Technical Manual 133
Discontinuity Time - The time on the most recent occasion at which one or more of this
interface's counters suffered a discontinuity.
In Octets - The total number of octets received on the interface, including framing characters.
In Unicast Pkts - The number of packets, delivered by this sub-layer to a higher (sub-)layer,
which were not addressed to a multicast or broadcast address at this sub-layer.
In Multicast Pkts - The number of packets, delivered by this sub-layer to a higher (sub-)layer,
which were addressed to a multicast address at this sub-layer.
In Discards - The number of inbound packets which were chosen to be discarded even though
no errors had been detected to prevent their being deliverable to a higher-layer protocol. One
possible reason for discarding such a packet could be to free up buffer space.
In Errors - For packet-oriented interfaces, the number of inbound packets that contained
errors preventing them from being deliverable to a higher-layer protocol.
Out Octets - The total number of octets transmitted out of the interface, including framing
characters.
Out Unicast Pkts - The total number of packets that higher-level protocols requested be
transmitted, and which were not addressed to a multicast or broadcast address at this sub-layer,
including those that were discarded or not sent.
Out Discards - The number of outbound packets which were chosen to be discarded even
though no errors had been detected to prevent their being transmitted.
Out Errors - For packet-oriented interfaces, the number of outbound packets that could not be
transmitted because of errors.
Ln Radio Status Monitoring:
Interfaces / LnRadio ---> Status / Ln Radio
Figure 3-69. Licensed Narrowband (LN) Status
The following status items appear on both APs and Remotes (unless stated otherwise)
Init Status - State of the NIC Initialization
- Off - Not operating
- Initializing - Powering on the NIC
- Discovering - Determining the NIC address
- Reprogramming - Programming the NIC firmware
General

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MDS ORBIT MCR and is the answer not in the manual?

GE MDS ORBIT MCR Specifications

General IconGeneral
BrandGE
ModelMDS ORBIT MCR
CategoryNetwork Router
LanguageEnglish

Related product manuals