Chapter 5 Detailed Descriptions of I/O Modules
GFK-2958E RSTi-EP User Manual 196
Operating Principle of the Hysteresis with Counter Value = Comparison Value
1 Comparison condition met status bit is set and hysteresis activated
2 Comparison condition not met, leaving the hysteresis range status bit is reset
3 Comparison condition met status bit is set and hysteresis activated
4 Leaving the hysteresis range and comparison condition not met status bit is reset
5 Comparison condition met status bit is set and hysteresis activated
6 Comparison condition met and hysteresis active status bit remains set
7 Leaving the hysteresis range and comparison condition no longer met status bit is reset