Chapter 5 Detailed Descriptions of I/O Modules
GFK-2958E RSTi-EP User Manual 212
Specifications EP-5261
Process, parameter and diagnostic data depend on the network
Adapter used (refer to the table in the section, Order and
Arrangement of the Modules)
RSTi-EP I/O communication bus
RS232, RS485, RS422, parameterizable
300 ... 115200 Bps, parameterizable
Current of power supply output
DIN 66020, DIN 66259, EIA-RS232C, CCITT V.24/V.28
Individual channel diagnosis
Current consumption from system current path I
SYS
,
Current consumption from input current path I
IN
For additional general data, refer to the section, General Technical Data for I/O Modules.
Overview of the Editable Parameter EP-5261
Disabled (0) / RS232 (1) / RS485 (2) / RS422 (3)
300 (0) / 600 (1) / 1200 (2) / 2400 (3) / 4800 (4) / 9600 (5) / 14400 (6) /
19200 (7) / 28800 (8) / 38400 (9) / 57600 (10) / 115200 (11)
None (0) / Even (1) / Odd (2)
None (0) / CTS/RTS (1) / XON/XOFF (2)
Terminating resistor RS485/422
1) Values in brackets for EtherCAT and Modbus-TCP
2) The option “7 Bit“ works only in combination with a parity ("even" or "odd")