Specifications EP-3804
Process, parameter and diagnostic data depend on the
network adapter used (refer to the table in the section, Order
and Arrangement of the Modules)
RSTi-EP I/O communication bus
J, K, T, B, N, E, R, S, L, U, C, mV
Conversion time ≥ 80 ms: 10 μV + 0.1 % of voltage
measurement range (without cold-junction measurement error)
0,25 mA for the cold-junction compensation with a Pt1000
Cold junction compensation
Internal and external (Pt1000), int. accuracy ≤ 3 K
-200 to +2315°C (-328 to 4199 °F)
Reverse polarity protection
Individual channel diagnosis
Current consumption from system current path I
SYS
,
Current consumption from input current path I
IN