Rack and pinion hoist
Assembly and Operating Instructions
29 / 100 BL108 GB Edition 03.2018 Rev. 02
3.4 Technical Data
3.4.1 Operating and environmental conditions
The machine must only be operated when the following operating and
environmental conditions are satisfied:
Temperature range
minimum -20°C
maximum +40°C
Wind speed
Operation/maintenance/servicing maximum 72 km/h
Installation maximum 45 km/h
The height-dependent variation in wind speed must be taken into
account. It may be necessary to cease/prohibit operation of the
machine under extreme weather conditions (e.g. thunder storm or sand
and snow storms), even if the operating and environmental conditions
fall within the bounds of those stated.
The operating company must provide appropriate precautions in this
regard.
Atmosphere
The atmospheric composition on-site must be suitable for people to
remain for longer periods in the area. In particular, reduction in the
oxygen concentration as a result of displacement or consumption must
be prevented. The legal limit values for pollutant
concentrations/aerosols and dust in the workplace must not be
exceeded.
Transporting material
When transporting material, this must not lead to a concentration of
abrasive/corrosive substances. If this cannot be safely excluded, then
the corrosion protection and/or the functional reliability of the electrical
components must be inspected at regular intervals and, if necessary,
replaced.
The generation/accumulation of (explosive) fine particulate matter must
be prevented/removed immediately.
Assembly site elevation
Up to max. 1000 m above sea level.
The technical data, such as the load capacity, is only ensured up to this
assembly site elevation. (Motor heating)