3.5.1 Anchoring forces
For the anchoring forces, refer to the following tables. Details are given
of the peak forces occurring for the assembly geometry shown; they do
not include any safety factors.
The anchoring forces apply for all the wind regions in Europe.
Extreme locations may require exceptions.
Local conditions such as:
mountains, bays, valleys,
house gullies, thoroughfares, buildings, etc.
can generate wind turbulence and such exceptions.
Assembly height H
[m]
Wind forces for geographical regions [N/m²]
A/B
C
D
E
0<H10
544
741
968
1225
10<H20
627
853
1114
1410
20<H50
757
1031
1347
1704
50<H100
879
1196
1562
1977
100<H150
960
1306
1706
2159