Rack and pinion hoist
Assembly and Operating Instructions
78 / 100 BL108 GB Edition 03.2018 Rev. 02
8.5.3 Safety gear replacement
GEDA safety gears must be replaced with GEDA safety gear in
accordance with the following time intervals (safety gear exchange
units).
Safety gears
replacement
interval*)
GEDA rack and pinion hoists with explosion
protection (ATEX, NEC, …)
every 3 years
GEDA gear rack hoists for offshore systems
(NORSOK, …)
every 3 years
GEDA rack and pinion hoists in accordance
with ASME A17.1 (USA …)
every 5 years
GEDA rack and pinion hoists without special
protective measure
every 6 years
*) If national or other rules / regulations stipulate a shorter replacement
interval, that has precedence over the replacement intervals stated
here.
The obligation for replacement is applicable to all GEDA rack and
pinion hoists.
The only criterion applicable for replacing is the entry in the
commissioning protocol in the operating manual for the safety gear and
test log / test report / transfer protocol / documentation of the checks
(Appendix in the maintenance manual) for initial commissioning and
replacement of the safety gear.
Other criteria are not permitted (e.g. period of use / operating hours /
number of drop tests etc.).
If not documented, the year of manufacture of the safety gear
applies!
That can result in a shorter replacement interval.