Index
MENUMENU
MENUMENU
MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 111
Example:
if Full scale speed parameter changes from 1500rpm to 3000 rpm, Autotune must be
repated.
Interval Range
1 0 ... 2048
2 2049 ... 4096
3 4097 ... 8192
4 8193 ... 16384
B0D STARTUP / Drv & Mot config / Mot data
B0D.00 Motor rated volt [V] RW D.Size Calc/Calc FK V-F-S-B Easy 670
Motor rated voltage
B0D.01 Motor rated freq [Hz] RW D.Size Calc/Calc FK V-F-S Easy 680
Motor rated frequency.
B0D.02 Motor rated curr [A] RW D.Size Calc/Calc FK V-F-S-B Easy 690
Motor rated current.
NOTE! The value should be not less then approx 0.3 times the drive rated current (output
current Class 1 @ 400V on the motor nameplate).
B0D.03 Motor rated spd [rpm] RW D.Size Calc/Calc FK V-F-S-B Easy 700
Motor full load speed at the rated frequency.
If Slip is available on the motor nameplate data, set the parameter value as following:
Mot rated speed = Synchronous speed - Slip
B0D.04 Motor rated pwr [kW] RW D.Size Calc/Calc FK V-F-S Easy 710
Motor rated power.
NOTE! For a motor nameplate rated in Hp, set Motor rated power [kW] = Motor Hp rating
* 0.736
B0D.05 Motor power fact N/A RW D.Size Calc/Calc FK V-F-S Easy 720
Motor rated power factor.
B0D.06 Motor efficiency N/A RW D.Size Calc/Calc FK V-F-S Full 730
Motor Efficiency (if not available, leave the default data).
B0D.07 Load default mot Full
It selects and loads the motor standard parameters: