Index
MENUMENU
MENUMENU
MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 136 ARTDrive V2 series - Instruction Manual
C01.14 AI 1 offset [%] RWS 0 -100/100 PP V-F-S-B Easy 5001
Analog Input 1 offset count value 100% is equal to 10V or 20mA.
C01.15 AI 1 filter [sec] RWS 0.0064 0.00/4.096 PP V-F-S-B Full 5006
Time constant of the Analog Input 1 filter.
C01.16 AI 1 low lim [cnt] RWS -16384 -32768/32767 PP V-F-S-B Full 5007
Lower limit of the Analog Input 1 block output in count (see Figure C.01).
C01.17 AI 1 hi lim [cnt] RWS 16383 -32768/32767 PP V-F-S-B Full 5008
Upper limit of the Analog Input 1 block output in count (see figure above).
C01.18 AI 1 offs tune / Start?
Autotune command for the Analog Input 1 offset. Input automatic fine-tuning.
To run the autotune, put the input signal to its minimum value and execute “Start ?”
command.
C01.19 AI 1 gain tune / Start?
Autotune command for the Analog Input 1 gain. Conditions containing an offset can be
compensated.
To run the autotune, put the input signal to its maximum value and execute “Start ?”
command.
C01.20 AI 1 output [cnt] R 0.00 -32768/32767 PV V-F-S-B Easy 5009
Analog Input 1 output count displaying.
C01.21 AI 1 < thr N/A R 0 0/1 DV V-F-S-B Full 5010
Display of threshold compensator state of Analog Input 1 (1 = the condition is true).