Index
MENUMENU
MENUMENU
MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 140 ARTDrive V2 series - Instruction Manual
C03.01 AI 3 alt sel src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Full 5052
Ipa 4000 - NULL = Default
It connects the selected signal to the selector of the alternative reference for An. Inp. 3
block.
ªª
ªª
ª
Pick List 3
C03.10 AI 3 type N/A RWS 0 0/2 DP V-F-S-B Easy 5040
[0] -10V .. +10V As for “ AI 1 type” parameter description above
[1] 0.20mA,0.10V As for “ AI 1 type” parameter description above
[2] 4..20mA As for “ AI 1 type” parameter description above
NOTE! “An inp 3 type” selection requires a correct jumpers configuration of RV33
regulation card:
-10V...+10V & 0..10V S8=OFF – S9=OFF – S10=OFF
0..20mA & 4..20mA S8=ON – S9= ON – S10= ON
C03.11 AI 3 alt value [cnt] RWS 0 32767/-32767 PV V-F-S-B Full 5042
Alternative reference value in count for Analog input 3
C03.12 AI 3 thr [%] RWS 20 -100/100 PP V-F-S-B Easy 5043
Analog Input 3 threshold value 100% is equal to 10V or 20mA.
C03.13 AI 3 scale N/A RWS 1 -16/16 PP V-F-S-B Easy 5044
Analog Input 3 scale factor.
C03.14 AI 3 offset [%] RWS 0 -100/100 PP V-F-S-B Full 5041
Analog Input 3 offset count value 100% is equal to 10V or 20mA.
C03.15 AI 3 filter [sec] RWS 0.0064 0.00/4.096 PP V-F-S-B Full 5046
Time constant of the Analog Input 3 filter.
C03.16 AI 3 low lim [cnt] RWS -16384 -32768/32767 PP V-F-S-B Full 5047
Lower limit of the Analog Input 3 block output in count (see figure of Analog Input 1).
C03.17 AI 3 hi lim [cnt] RWS 16383 -32768/32767 PP V-F-S-B Full 5048
Upper limit of the Analog Input 3 block output in count (see figure of Analog Input 1).