MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 183
D08 REF&RAMP / Mlt speed
D08.00 MltSpd sel 0 src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Easy 7072
Ipa 4000 - NULL = Default
Multi speed 1 selector source: it allows to select the origin of the signals stating the input
combination.
ªª
ªª
ª
Pick List 3
D08.01 MltSpd sel 1 src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Easy 7073
Ipa 4000 - NULL = Default
Multi speed 2 selector source: it allows to select the origin of the signals stating the input
combination.
ªª
ªª
ª
Pick List 3
D08.02 MltSpd sel 2 src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Full 7074
Ipa 4000 - NULL = Default
Multi speed 3 selector source: it allows to select the origin of the signals stating the input
combination.
ªª
ªª
ª
Pick List 3
D08.03 Mlt spd 0 src N/A RWS Ipa7060 PList 11 PIN V-F-S-B Easy 7071
Ipa 7060 - Mlt spd 0 = Default
Multi speed 0 source: it allows to select the origin of the signals of Multi speed 0 set.
ªª
ªª
ª
Pick List 11
D08.04 Mlt spd 1 src N/A RWS Ipa7061 PList 11 PIN V-F-S-B Easy 7076
Ipa 7061 - Mlt spd 1 = Default
Multi speed 1 source: it allows to select the origin of the signals of Multi speed 1 set.
ªª
ªª
ª
Pick List 46
D08.10 Mlt spd 0 [rpm] RWS 0.00 Calc/Calc PV V-F-S-B Easy 7060
Digital Multi Speed 0 value