MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 186 ARTDrive V2 series - Instruction Manual
D09 REF&RAMP / Motopot
D09.00 Mpot up src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Easy 7091
Ipa 4000 - NULL = Default
It allows to select the origin of the signals of Motopot up command.
ªª
ªª
ª
Pick List 3
D09.01 Mpot down src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Easy 7092
Ipa 4000 - NULL = Default
It allows to select the origin of the signals of Motopot down command.
ªª
ªª
ª
Pick List 3
D09.02 Mpot invers src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Easy 7093
Ipa 4000 - NULL = Default
It allows to select the origin of the signals to invert the Motopot reference signal.
ªª
ªª
ª
Pick List 3
D09.03 Mpot preset src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Easy 7094
Ipa 4000 - NULL = Default
It allows to select the origin of the preset command.
ªª
ªª
ª
Pick List 3
D09.10 Mpot lower lim [rpm] RWS 0.00 0.00/0.00 PP V-F-S-B Easy 7080
Motopot reference lower (minimum) limit
D09.11 Mpot upper lim [rpm] RWS (*) 0.00/0.00 PP V-F-S-B Easy 7081
(*) 1500(Europe)
1800(American)
Motopot reference upper (maximum) limit
D09.12 Mpot Acc Time [sec] RWS 5 0.01/10000 PV V-F-S-B Easy 7083
Motopot acceleration ramp time
D09.13 Mpot Dec Time [sec] RWS 5 0.01/10000 PV V-F-S-B Easy 7085
Motopot deceleration ramp time

Table of Contents