MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 198 ARTDrive V2 series - Instruction Manual
REG PARAM / V/f SaveE
The function allows to reduce the motor Flux in order to reduce the losses.
As a consequence it is possible to obtain an energy saving when the load requires a
reduced torque as compared to the rated one (save energy).
Through the input sources it is possible to select the origin of the save energy command
signal and of the signal stating the flux level.
The sources are:
- E06.00 - SE cmd src save energy command source
- E06.01 - SE flx level src source of the flux level value during the save energy
In the configurations it is possible to set via E06.02 - Dig SE flx level a digital percentage
value stating the flux level and via E06.03 - SE flx ramp time a ramp time on the level.
V out
f
SAVE ENERGY
SE flux ramp time
SE cmd src
SE flux level src
Figure E06: Save energy block
E06 REG PARAM / V/f SaveE
E06.00 SE cmd src N/A RWS Ipa4000 PList 3 PIN V Easy 3538
Ipa 4000 - NULL = Default
It select the origin of the signal of V/f Save Energy command.
ªª
ªª
ª
Pick List 3
E06.01 SE flx level src N/A RWS Ipa3536 PList 23 PIN V Easy 3539
Ipa 3536 - Dig SE flx level = Default
It select the origin of the signal of V/f Save Energy Flux Level.
ªª
ªª
ª
Pick List 23