Index
MENUMENU
MENUMENU
MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 254 ARTDrive V2 series - Instruction Manual
L06.01 EF activity N/A RWS 3 2/6 DP V-F-S-B Easy 9060
External fault activity:
[2] Warning
[3] Disable drive
[4] Stop
[5] Fast stop
[6] Curr limstp
L06.02 EF restart N/A RWS 0 0/1 DP V-F-S-B Easy 9061
External fault restart:
[0] off
[1] on
L06.03 EF restart time [ms] RWS 1000 0/30000 PP V-F-S-B Easy 9062
External fault restart time
L06.04 EF hold off [ms] RWS 0 0/30000 PP V-F-S-B Easy 9600
External fault hold off
L07 ALARM CFG / Motor OT
Motor Over-Temperature indicated via thermal contact or PTC thermistor on 78-79 drive
regulation board terminals.
L07.00 MOT activity N/A RWS 2 2/6 DP V-F-S-B Easy 9065
Motor Over-Temperature activity:
[2] Warning
[3] Disable drive
[4] Stop
[5] Fast stop
[6] Curr limstp
L07.01 MOT restart N/A RWS 0 0/1 DP V-F-S-B Easy 9066
Motor Over-Temperature restart:
[0] off
[1] on
L07.02 MOT restart time [ms] RWS 1000 0/30000 PP V-F-S-B Easy 9067
Motor Over-Temperature restart time