EasyManua.ls Logo

GEFRAN-SIEI ARTDrive Vector V2 Series - Page 255

GEFRAN-SIEI ARTDrive Vector V2 Series
387 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Index
MENUMENU
MENUMENU
MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 255
L07.03 MOT hold off [ms] RWS 1000 0/30000 PP V-F-S-B Easy 9603
Motor Over-Temperature hold off
L08 ALARM CFG / Hsink OT
Heatsink Sensor Over-Temperature (detected by a sensor).
L08.00 HTS activity N/A RWS 3 2/6 DP V-F-S-B Easy 9054
Heatsink Sensor Over-Temperature activity:
[2] Warning
[3] Disable drive
[4] Stop
[5] Fast stop
[6] Curr limstp
L08.01 HTS restart N/A RWS 0 0/1 DP V-F-S-B Easy 9055
Heatsink Sensor Over-Temperature restart:
[0] off
[1] on
L08.02 HTS restart time [ms] RWS 1000 0/30000 PP V-F-S-B Easy 9056
Heatsink Sensor Over-Temperature restart time
L08.03 HTS hold off [ms] RWS 1000 0/30000 PP V-F-S-B Easy 9604
Heatsink Sensor Over-Temperature hold off
L09 ALARM CFG / Reg OT
Regulation card Sensor Over-Temperature
L09.00 RGS activity N/A RWS 3 2/6 DP V-F-S-B Easy 9057
Regulation card Sensor Over-Temperature activity:
[2] Warning
[3] Disable drive
[4] Stop
[5] Fast stop
[6] Curr limstp

Table of Contents