ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 293
O03 APPL CFG / PI ctrl
NOTE! Menu accessible with Access Level = FULL.
O03.00 PID PI enab src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Full 7260
Ipa 4000 - NULL = Default
Source of the PI section enable signal.
ªª
ªª
ª
Pick List 3
O03.01 PID I freeze src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Full 7261
Ipa 4000 - NULL = Default
Source of the PI section Freezing signal.
ªª
ªª
ª
Pick List 3
O03.02 PIGP ref src N/A RWS Ipa7281 PList 36 PIN V-F-S-B Full 7280
Ipa 7281 - Dig PIGP ref = Default
Source of the gain adaptive signal.
ªª
ªª
ª
Pick List 36
O03.10 PID Mlt PI sel 0 N/A RWS Ipa4000 PList 3 PIN V-F-S-B Full 7320
Ipa 4000 - NULL = Default
Source of the selector 0 signal of the starting multiplier.
ªª
ªª
ª
Pick List 3
O03.11 PID Mlt PI sel 1 N/A RWS Ipa4000 PList 3 PIN V-F-S-B Full 7321
Ipa 4000 - NULL = Default
Source of the selector 1 signal of the starting multiplier.
ªª
ªª
ª
Pick List 3
O03.12 PID Mlt PI 3 src N/A RWS Ipa7326 PList 38 PIN V-F-S-B Full 7322
Ipa 7326 - Dig PID Mlt PI 3 = Default
Source of the multiplier 3 signal, example diameter sensor.
ªª
ªª
ª
Pick List 38