If the selected connector channel is already in use by another Control Room speaker system
this allowed and that physical speaker will be shared between both speaker systems.
Note: CR1, CR2, and CR3 are all relay selected from the same 8 channel DAC. Therefore you
can not define a speaker system to contain signals going to the same channel on more than one of
these connectors. Channels 1 and 2 are switched together to all three output connectors. Because
of this channels 1 and 2 can only be routed to the same connector.
Page 84 of 135 Table Of Contents
Illustration 76: Channel Routing Conflict Dialog