m908 User Manual, Rev. G
The following parameters control the Bass Management processing:
crossover Selects the crossover frequency. Range is <50-150Hz>
hpf slope Sets the high pass filter slope. Options are <6, 12,18, 24dB/octave><bypass>
If bypass is selected then a full range unfiltered signal is sent to the speaker.
lpf slope Set the low pass filter slope. Options are <6, 12,18, 24dB/octave><off>
If <off> is selected then no signal is sent to the sub woofer.
sub mode Push the VOLUME encoder to adjust the sub output mode <mono, left, right>
Press the SETUP switch to save and exit Setup Mode.
Note: To bybass the Bass Management processing on all channels see the bass management
bypass in Monitor Control setup.
6.3.9 SOLO/MUTE Setup
The 8 SOLO/MUTE switches can be "paged" across 3 pages for a total of 24 controls.
Each switch can be mapped to one or more speaker channel.
Push the SETUP switch then press-hold the SOLO/MUTE switch to enter the Solo/Mute setup
screen.