5-18
10
Press [2] key (SCAN). The following message is displayed.
Following message is displayed.
11
&RQÀUPWKDWWKHWRROLVDWWKHSRVLWLRQVKRZQLQWKHOHIWLPDJH
(grey square area), and press the [ENTER] key.
It will scan the registration mark, and then plot the registration mark for
comparison. It will return to SENSOR OFFSET ADJ. screen once the
plotting is completed.
Feed direction of media
'LVWDQFHDGMXVWPHQWYDOXH<
Distance
DGMXVWPHQW
value X
Registration mark for
DGMXVWPHQW
Registration mark for
comparison
Feed direction of media
Align the tool to this area
Supplement
Position of the registration mark is measured at
the center of the line.
12
Using the registration mark plotted in step 9, measure the
GLVWDQFHRIKRZPXFKWKHDGMXVWPHQWUHJLVWUDWLRQPDUN
needs to be moved so both will overlap, and record the
YDOXH$VDQH[DPSOHLQWKHÀJXUHDERYHLWQHHGVWRPRYH
in negative directions for both X and Y directions, so both of
WKHDGMXVWPHQWYDOXHVZLOOEHQHJDWLYHYDOXHV
13
Press the [3] key (X).
SENSOR OFFSET ADJ. X screen is displayed.
Supplement
You can set the range between -3.0mm and
+3.0mm.
14
Press the POSITION ( ) keys and increase or decrease the
setting value. Set the X value measured in step 12.
15
&RQÀUPWKHVHWWLQJDQGSUHVVWKH>(6&@NH\35(9,286
6(16252))6(7$'-ZLOOEHFRQÀUPHGDQGLWZLOOUHWXUQWR6(1625
OFFSET ADJ. screen.