Model 574 Programmable Counting System (PCS)
190 - GSE Scale Systems
8210%s0%e P8210.0 Activ above
8211%s0%e P8211.0 Hold 0.0 S
8212%s0%e P8212.0 Macro 0
8213%s0%e P8213.0 Mot'n Ign'd
8214%s0%e P8214.0 Basis New # (Fixed)
8215%s1.000000%e P8215. AL: 1.
8230%s1%e P8230.1 DeAct Below
8231%s0%e P8231.0 Hold 0.0 S
8232%s16%e P8232.X Macro none
8233%s0%e P8233.0 Mot'n Ign'd
8234%s0%e P8234.0 Basis New # (Fixed)
8235%s1.000000%e P8235. DL: 1.
8250%s13%e P8250.X Par13 TrNet
CONCLUSION: The truck net wt. register and the
setpoint are the “key” to this whole
operation. The truck net wt. is not
calculated until an “out weighment” is
performed. Until then this register
retains the last calculated value until
the next out weighment or a new value
is entered into this register from
within a macro. Once an out
weighment is performed and motion
stops a new truck net wt. is calculated.
The setpoint is set to trip when the
truck net weight reg. exceeds 1 pound
(any number greater than 0). Note
that the setpoint is based on the
“Truck Net Wt.” Once the setpoint is
tripped a macro is set to be invoked.
This particular example will perform
an accumulation to the truck net
weight. After the macro operations
are executed the final step in the
macro is to insert a “0” into the truck
net wt. reg. This will reset the
setpoint to allow it to be tripped after
the next out weighment is performed.