Model 574 Programmable Counting System (PCS)
268 - GSE Scale Systems
was beyond the range of valid
choices.
14 Must Keyin The choice for the current
parameter must be keyed in.
15 Size>998 ! The size of one of the Custom
Transmit setups has exceeded
the limit.
16 Check Swtch A programming operation
was attempted when the
program access switch is in
the NO position. Setting this
switch to the NO position will
prohibit any programming
changes.
29.4 Hardware Problem Error Messages
20 Deflt A/D This message is displayed for
1 second. It will be displayed
if the A/D calibration data is
gets corrupted by whatever
means. When the
information modes are
accessed (P61100) the
message will be displayed for
1 second and P61113 - 16 are
defaulted to a factor of 1.
This message will also be
displayed on power-up if the
check-sum for the A/D data
are corrupted. P61113 - 16
are also reset to a factor of 1.
21 EEROMerror Error reading data from the
EEPROM. Possible U1 or U2
problem.
22 EEROMerror Error writing data to
the EEPROM.
Possible U1 or U2 problem.
23 CheckU1 Supplementary error message
for above errors.
24 EEROMFull! The setup being attempted
requires more EEPROM than
is currently installed.
25 DefltSetup Upon power-up the system
has not found the proper
codes. Therefore all
parameters have been reset to
factory default values.
26 Bad Setup The stored data has a
checksum error. Check all
parameters or re-load setup.
27 RE-BOOT! The unit cannot use the
EEPROM for data storage, so
it is attempting to power-up
again to cure the problem.
28 NoRAMAVAIL The current setup requires
more RAM than is currently
installed. Either contact your
dealer or the factory.
29 PIN error This message will appear on
power-up or setup if the E
2
is
corrupted in the PIN section.
Check E
2
for problems. The
access code is then defaulted
to the factory (GSE) access
code. Also refer to Error 11.
29.5 Calibration Error Messages
30 F.S.>MAX! The entered calibration
weight, together with the
currently applied signal,
indicates that the full scale
signal will be greater than the
allowed maximum of the
unit. Verify that correct
entries have been made for
the capacity, P110, and for
the calibration weight. If all
appears correct, refer to the
use of the information
parameter P61100, and
determine the output (in mv /
volt) of the connected load
cell.
31 F.S.<.1mVv The entered calibration
weight, together with the
currently applied signal,
indicates that the full scale
signal will be less than the
allowed minimum of the
unit. Verify the proper
entries for the capacity, P110,
and for the calibration

Table of Contents