Model 574 Programmable Counting System (PCS)
26 - GSE Scale Systems
PARAMETER # SELECTION DESCRIPTION
Custom Units 2
P154.08 lb oz Sets the foruth units as
pounds-ounces
P154.09 * =NONE Disables the fourth units
P155.- -Ucon1 * 1.000 Enter the conversion factor
for the 1st Custom Units.
P156.- -Ucon2 * 1.000 Enter the conversion factor for
the 2nd Custom Units.
P157.- -Unam1 * ????1 Enter the name of the 1st
Custom Units.
P158.- -Unam2 * ????2 Enter the name of the 2nd
Custom Units.
MODEL TYPE, TARE
& ACCUMULATION
P160.00 Model * 574 Shows the System model type
P161.00 TrSAV * Disbl Select whether or not you want
to saveTare Weight on
power-down
P161.01 Enbld
P162.00 TrNEG * Disbl Select whether or not to be
able to tare out negative
numbers
P162.01 * Enbld
P163.00 TrRND Disbl Elect whether or not to round
off tare values.
P163.01 * Enbld
P164.00 AcRTZ 0.01% Enter how close the platform
must be to zero in
P164.01 0.02% terms of Full Scale in order to
perform an
P164.02 0.05% Accumulation
P164.03 * 0.1%
P164.04 0.2%
P164.12 100.%
P165.00 AcFnc BOTH Select whether to add,
subtract or be able to do
P165.01 * ADD do both when accumulating.
P165.02 SUB
KEY DISABLING
P166.00 AutoT Disbl Enable/disable use of auto-
tare operation