Chapter 4 Parameter Setup (Advanced) Technical Reference Manual
PARAMETER # SELECTION DESCRIPTION
SECTION - 4.6
166.01 * Enbld
P167.00 KybdT Disbl Enable/disable keyboard tare
operation
P167.01 * Enbld
P168.00 KybdS Disbl Enable / disable numeric
keyboard Weigh Mode
P168.01 * Enbld selections
P169.00 GrENT * Disbl Enable / disable keyboard
entry of the Gross Weight
P169.01 Enbld (NOT H-44)
ANALOG OUTPUT ** This option is not
available on the
OPTION 574. Contact GSE for more
information. **
P170.00 A-out * off Turn Analog Output option on
or off (if installed).
P170.01 on
P171.00 Parm Gross If P170.01 is selected, this
establishes which of
P171.01 Net the numeric parameters the
Analog Output option will be
P171.02 Tare based upon, most commonly
P171.03 GrTOT Gross or Net.
P171.04 GrT+C
P171.05 GrT-C
P171.06 NtTOT
P171.07 NtT+C
P171.08 NtT-C
P171.12 TrGrs
P171.13 TrNet
P171.14 TrTar
P171.91 Reg#1
P171.92 Reg#2
P171.93 Reg#3
P171.94 Reg#4
P172.- -F.S.= XXX.XXX The value entered here sets
the weight which will set the
Analog Output voltage to
10 volt (or output current to
20 mA)