Model 574 Programmable Counting System (PCS)
28 - GSE Scale Systems
PARAMETER # SELECTION DESCRIPTION
PARTS COUNTING
MODE (570/574)
P180.00 ASmpl off Turn Auto Sample Accept on
P180.01 on or off
P181.00 AEnhn off Turn Auto-Enhance on or off
P181.01 on
P182.00 SmpSz None! Sets default sample size
P182.-- 1 to 9999
P183.00 %Accy None! Sets Piece Weight Accuracy
P183.-- 90.00 to 99.96 Select in .04% increments
P184.00 AcDsp off Display Current Piece
P184.01 on Weight Accuracy
P185.00 ErFac 0.1 to 20 Accuracy Error Factor
P186.00 PreSm None! Pre-Sample Scale Switch
P186.01 Scl1 Scale 1
P186.02 Scl2 Scale 2
P186.03 Scl3 Scale 3
P186.04 Scl4 Scale 4
P187.00 AftSm None! After-Sample Scale Switch
P187.01 Scl1 Scale 1
P187.02 Scl2 Scale 2
P187.03 Scl3 Scale 3
P187.04 Scl4 Scale 4
P188.— Res1 * Count res/scl 1 Scale 1 count resolution value entered.
P189.— Res2 Count res/scl 2 Scale 2 count resolution value entered.
P190.— Res3 Count res/scl 3 Scale 3 count resolution value entered.
SAMPLING
P192.00 SmpFl * None! Selects filter used during sampling.
P193.00 AcEnf * off Enforce accuracy during sample.
P193.01 AcEnf on Set at P183.
TRANSMISSION
PROTOCOL
P200.00 Baud 19200 Set the baud rate for both Print
and Comm ports
P200.01 * 9600
P200.02 4800
P200.03 2400
P200.04 1200
P200.05 600
P200.06 300
P200.07 150

Table of Contents