GSE Scale Systems - 29
Chapter 4 Parameter Setup (Advanced) Technical Reference Manual
PARAMETER # SELECTION DESCRIPTION
SECTION - 4.6
P201.00 #data 7bits Select the number of data bits
for the transmission
P201.01 * 8bits
P202.00 Par'y * none Select the parity for all
transmissions.
P202.01even
P202.02 odd
P203.00 #stop * 1bit Select the number of stop bits
for all transmissions
P203.01 2bits
P204.00 ComHS none Select the type of handshake
used by the Com Port
P204.01 CTS for sending and receiving.
P204.02 * Xon
P204.03 both
P205.00 PrnHS * none Select the type of handshake
used by the Print Port
P205.01 CTS
P206.00 RxCom off Enable or disable the receiver
for the Com Port.
P206.01 * on
P207.00 TxRTZ 0.01% Select a return range for use
with the weighment
P207.01 0.02% transmission in percentage of
Full Scale.
P207.02 0.05%
P207.03 * 0.1%
P207.04 0.2%
P207.05 0.5%
P207.12 100.%
P208.00 Width =0 Select the number of
characters transmitted for
P208.01 =1 numeric parameters if a fixed
width format is used
P208.02 =2 for the Custom Transmits.
P208.03 =3
P208.04 =4
P208.08 * =8
P208.15 =15
P209.00 TxHld * delay Will delay or abort a
transmission when the
P209.01 abort transmit buffer is full