Model 574 Programmable Counting System (PCS)
36 - GSE Scale Systems
PARAMETER # SELECTION DESCRIPTION
TIME-DATE AND
ALARM
PARAMETERS
P500.SS Time HH:MM Enter correct time here if
needed.
P501.YY Date DA/MO Enter correct date here if
needed.
P502.00TmDat * no Determine whether or not the
time and date will
P502.01 yes be displayed upon power-up.
P503.00AM/PM no Determine whether time will
use 12 hour or 24
P503.01 * yes hour clock.
P504.00A1Sel * off Set the operating conditions
for Alarm 1. Off dis-
P504.01 intvl ables alarm; INTVL sets an
interval; daily sets
P504.02 daily alarm for once a day.
P505.SS A1Tim HH:MM Set time factor for Alarm 1.
P506.00 A2Sel * off Set the operating conditions
for Alarm 2.
P506.01 intvl
P506.02 daily
P507.SS A2Tim HH:MM Set time factor for Alarm 2.
P508.00 A3Sel * off Set the operating conditions
for Alarm 3.
P508.01 intvl
P508.02 daily
P509.SS A3Tim HH:MM Set the time factor for Alarm 3.
P510.00 Style * U.S.A Determine the style of
the Time-Date display.
P510.01 Int'l
P511.00 RtDsp * Time and Date
P511.01 Time Only
P511.02 Date Only
P511.03 Number
P512.00 A1Dsp * Time and Date Alarm#1
P512.01 Time Only
P512.02 Date Only
P512.03 Number
P513 Same as P512 for Alarms #2
thru * through #4
515