GSE Scale Systems - 51
Chapter 4 Parameter Setup (Advanced) Technical Reference Manual
PARAMETER # SELECTION DESCRIPTION
SECTION - 4.6
The set of available choices for P5137 depends upon the selection made in P5136. If set for P5136.0 you will
be able to select from the set immediately below: if set for any other selection, you will be restricted to the
second set of selections below.
P5137.0 Value Var#0 Based on variable # 0
P5137.1 Var#1 Based on variable # 1
P5137.2 Var#2 Based on variable # 2
thru thru
P5137.9 Var#9 Based on variable # 9
OR
P5137.0 Value * AL Based on the lower activation
parameter.
P5137.1 AU Based on the upper activation
parameter.
P5137.2 DL Based on the lower de-
activation parameter.
P5137.3 DU Based on the upper de-
activation parameter.
P5138.0 Basis new # Upper De-activate Target
value is a specific value
P5138.1 % val The entered Upper De-
activate value for this setpoint
is a % multiplier of another (to
be specified) variable.
P5138.2 diff The entered Upper De-
activate value for this setpoint
is subtracted from another (to
be specified) variable.
P5139. AU: XXX.XX De-activate value upper limit.
Note if P5138 is " % val " or is
" diff " then this value is a per-
centage of or difference of
another value.
P5140.0 Based Var # Based on one of ten variables,
P80 - P89, which are accessible during
normal operation.
P5140.1 SPt 1 Based on one of setpoint #1's
values.
P5140.2 SPt 2 Based on one of setpoint #2's
values.
P5140. º SPt32 Based on one of setpoint #32's
values.