Windsor 500 User Manual - Issue C
-
17
-
Setting Methods
General
An authorised user can set the complete system or partly set the system by area from a Keypad or Keypoint
according to the user authority level, and the area authority allocated to the particular Keypad/Keypoint
Alternatively, where the system event programmer has been programmed to set an area of the system at a
predetermined time, the area will set automatically. All settings, or attempts to set the system or an area of
the system, are recorded in the system event log. Where the event programmer is used to set an area, it will
always set instantly at the pre-determined time. However, where setting is initiated from a Keypad, Keypoint,
the method of finally setting the system or area, will depend on the final setting method programmed by the
installation engineer for the particular Keypad/ Keypoint.
Group Setting
Where a system has been programmed for Group Setting, the set menu will display “Group” as one of the
available areas. Selection of Group Setting will display the current area set/unset status (set areas on the top
line and unset ones on the bottom line of the display). To select more areas for setting, press the numeric key
for the area/s you wish to set. New areas for setting will appear flashing on the top line. Press to set. All newly
selected areas will set according to the setting method programmed for the entire system.
Instant Setting
Where a Keypad (or Keypoint) has been programmed to 'Instantly Set' an area it will immediately set on
demand.
Final Exit Route Setting
Where the Keypad or Keypoint has been programmed for Route Setting of 'Final Exit’ setting, the area(s) will
finally set by closing the door designated as the 'Entry/Exit'. The exit tone will operate until the 'Entry/Exit' is
closed. The user must leave the area by the prescribed 'Exit Route'. If a user deviates from the prescribed
'Exit Route' during exit, the exit tone will change to a pulsing tone while the 'Non-Exit Route Circuit' is open or
activated.
Push Button Setting
If the Keypad or Keypoint is programmed for 'Push Button' setting , the system or area will finally set when a
push button, located outside the area, is activated. The exit tone will operate until the exit push button is
pressed. The user must leave the area by the prescribed 'Exit Route'. If a user deviates from the prescribed
'Exit Route' during exit, the exit tone will change to a pulsing tone while the 'Non Exit Route Circuit' is open or
activated.
Timed Setting
If an area or the system is programmed for 'Timed Setting' from a particular Keypad/Keypoint, the area(s) will
set on expiry of a pre-programmed 'Exit Time'. The user must leave the area by the prescribed ‘Exit Route'.
If a user deviates from the prescribed 'Exit Route' during exit, the exit tone will change to a pulsing tone while
the 'Non Exit Route Circuit' is open or activated.
Timed or Final Exit Route Setting
If programmed for 'EnEx or Timed' setting from a particular Route Setting Keypad/Keypoint, setting is
completed either by closing the 'Entry/Exit', or on expiry of the 'Exit Time', whichever is the sooner. The exit