Windsor 500 User Manual - Issue C
-
8
-
System And Area Event Log
The Windsor System incorporates a ’System Event Log’ capable of recording the most recent 300 events
occurring throughout the system. The ’System Event Log’ will record all events, i.e., user log-on log-off
times and user numbers, Keypad/Keypoint point numbers, setting and unsetting times, alterations made to
programmed settings, fault conditions, etc. When the ’System Event Log’ is full, the oldest event will be
automatically removed when the next event occurs.
An ’Area Alarm Log’ is also provided for each configured area of the system, each with the capacity to
record up to 10 alarm events. The ’Area Alarm Logs’ will only record the sequence of events relating to
alarm or abnormal conditions occurring in the log area during one set period or one unset period. Any
events in an area log will automatically be cancelled when the area is reset or set, providing circuits are
clear.
All log events are automatically date and time stamped and may be viewed, or printed on a system printer.
When printing the System Event Log’, the user (or engineer) can select the print-out to be filtered in order
of circuit number, user number, Keypad number or date.
Security Lighting Controls
Windsor 500 Systems are provided with facilities to control up to four individual light zones. If automatic
lighting control is incorporated in the system, each light zone will be switched on automatically if a Lighting
Detector detects movement. Additionally, each light zone can be programmed to switch on between pre-
programmed times or automatically at dusk and to switch off at a pre-programmed off time. In addition, light
zones can be manually controlled.
An authorised user or engineer can modify the security lighting Controls.