PSU Series Programming Manual
100
Minimum falling current slew rate is
0.001A/msec.
Maximum falling current slew rate is
rated current divided by 100msec.
SOUR:CURR:SLEW:FALL MAX
Sets the falling current slew rate to the maximum.
Returns the status of the output mode (CC, CV,
Off) of the power supply.
The interface will return “CV’ if the supply is in
Constant Voltage Mode, “CC” if the supply is in
Constant Current Mode or “OFF” if the supply
output is off.
Returns the output state as a string, “CC”,
“CV”, “OFF”
:SOUR:MODE?
>CC
The power supply is currently in CC mode.
[:SOURce]:RESistance[:LEVel][:IMMediate]
[:AMPLitude]
Sets or queries the internal resistance in ohms.
[:SOURce]:RESistance[:LEVel][:IMMediate][:AMPLitud
e] {<NR2>(OHM)|MINimum|MAXimum}
[:SOURce]:RESistance[:LEVel][:IMMediate][:AMPLitud
e]?
Resistance in ohms:
0 ohm ~ Rrated = Vrated/Irated