REMOTE CONTROL
115
The setting will only be valid after the power has been
cycled.
Syntax
Return Syntax
:SYSTem:CONFigure:CONTrol:RANG
{<NR1>|LOW|HIGH}
:SYSTem:CONFigure:CONTrol:RANGe?
Parameter
LOW | 0
5V [5kΩ]
HIGH| 1
10V [10kΩ]
Return Parameter
<NR1>
Returns the range setting.
Example
SYST:CONF:CONT:RANG LOW
SYST:REB
Set external analog control voltage (or resistance)
range to 0~5V [5kΩ] and reboot the unit to active
the setting.
:SYSTem:CONFigure:TRIGger:INPut:SOURce
Set
Query
Description
Sets or queries what action will be performed on
receiving a trigger.
Syntax
Return Syntax
:SYSTem:CONFigure:TRIGger:INPut:SOURce
{<NR1>|NONE|OUTPut|SETTing|MEMory}
:SYSTem:CONFigure:TRIGger:INPut:SOURce?
Parameter
NONE | 0
No input trigger.
OUTPut | 1
Toggles the output on receiving a
trigger.
SETTing | 2
Sets the voltage/current on receiving
a trigger.
MEMory | 3
Loads a memory setting on receiving
a trigger.
Return Parameter
<NR1>
Returns the input source.

Table of Contents

Other manuals for GW Instek PSU Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSU Series and is the answer not in the manual?

GW Instek PSU Series Specifications

General IconGeneral
BrandGW Instek
ModelPSU Series
CategoryPower Supply
LanguageEnglish

Related product manuals