114
OFF | 0
External control is not performed.
Return parameter
<bool>
Returns output status of the instrument.
Example
SYST:CONF:OUTP:EXT 1
SYST:REB
Active the external output control and reboot the
unit to active the setting.
:SYSTem:CONFigure:MONitor:RANGe
Set
Query
Description
This command is used to select the monitor
voltage range. This is the equivalent to the F-96
(Monitor Voltage Select) power on configuration
settings.
Note
The setting will only be valid after the power has been
cycled.
Syntax
Return Syntax
:SYSTem:CONFigure:MONitor:RANGe
{<NR1>|LOW|HIGH}
:SYSTem:CONFigure:MONitor:RANGe?
Parameter
LOW | 0
5V
HIGH | 1
10V
Return Parameter
<NR1>
Returns the range setting.
Example
SYST:CONF:MON:RANG LOW
SYST:REB
Set monitor voltage range to 0~5V and reboot the
unit to active the setting.
:SYSTem:CONFigure:CONTrol:RANGe
Set
Query
Description
This command is used to select the external
analog control voltage (or resistance) range. This
is the equivalent to the F-97 (Control Range)
power on configuration settings.

Table of Contents

Other manuals for GW Instek PSU Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSU Series and is the answer not in the manual?

GW Instek PSU Series Specifications

General IconGeneral
BrandGW Instek
ModelPSU Series
CategoryPower Supply
LanguageEnglish

Related product manuals