PSU Series Programming Manual
118
The setting will only be valid after the power has been
cycled.
:SYSTem:COMMunicate:ENABle {<bool>
|OFF|ON,GPIB|USB|LAN|SOCKets|WEB|SERial}
:SYSTem:COMMunicate:ENABle?
{GPIB|USB|LAN|SOCKets|WEB|SERial}
Disables the selected interface.
Enables the selected interface.
Returns the status of the selected
mode.
SYST:COMM:ENAB 1,USB
SYST:REB
Turns the USB interface on and reboot the unit to
active the setting.
SYST:COMM:ENAB? USB
1
Queries the USB state, returns 1 (USB is on).
:SYSTem:COMMunicate:GPIB[:SELF]:ADDRess
Sets or queries the GPIB address.
The setting will only be valid after the power has been
cycled.
:SYSTem:COMMunicate:GPIB[:SELF]:ADDRess
<NR1>
:SYSTem:COMMunicate:GPIB[:SELF]:ADDRess?